Annex No.1
Technical Specification of XXX XXXXXX
X pieces of X channels data loggers + XX pieces of 3 channels data loggers
Mandatory parameters
Value
Parameter
accomplished:
Yes/No
Real value
Sample Rate
>= 5000 sps
Internal Data Storage
yes
Removable Data Storage
yes
Data Type
miniSEED
Streaming Data Format
SeedLink
Ethernet
yes
A/D converter
>= 24 bit
Environmental protection (IP)
>= 67
Mass Centering/Locking/Unlocking
yes
Supply Voltage
9 – 30 V
External GNSS antenna
yes
Rated parameters
Value
Parameter
accomplished:
Yes/No
Real value
Maximum
Points
Dynamic Range typical @ 100 sps
>= 140 dB
10
Size of internal Storage
>= 8 GB
5
Size of Removable Storage
>= 32 GB
10
SOH in miniSEED format
yes
3
Operating Temperature
<= -20 ˚C
10
Timing Accuracy
<= 10 us
2
Power Consumption
<= 1.5 W
10
VPN
yes
5
Orientation Correction
yes
2
<br> 7 pieces of broadband seismometer
Mandatory parameters
Value
Parameter
accomplished:
Yes/No
Real value
Symmetric Triaxial
yes
Force Balance System
yes
Sensitivity
<= 1000 V/m/s
Bandwidth
10 sec to 100 Hz
Velocity Output
40 V
Environmental protection (IP)
>= 67
Supply Voltage
9 - 30 V
Rated parameters
Value
Parameter
accomplished:
Yes/No
Real value
Maximum
Points
Clip Level
>= 20 mm/s
10
Maximum Operating Tilt
>= 5˚
5
Dynamic Range typical @ 1Hz
>= 150 dB
5
Power Consumption
<= 0.5 W
10
Operating Temperature
<= -20 ˚C
10
Mass Centering required
no
3
<br> 9 pieces of accelerometers
Mandatory parameters
Value
Parameter
accomplished:
Yes/No
Real value
Symmetric Triaxial
yes
Force Balance System
yes
Maximum Full Scale Range
+-4 g
Minimum Full Scale Range
+-0.25 g
Bandwidth
DC to 200 Hz
Acceleration output
40 V
Supply Voltage
9 - 30 V
Environmental protection (IP)
>= 67
Rated parameters
Value
Parameter
accomplished:
Yes/No
Real value
Maximum
Points
Dynamic Range typical @ 1Hz
>= 155 dB
10
Power Consumption
<= 1.5 W
10
Operating Temperature
<= -20˚C
10
<br> 1 piece of accelerometer with integrated data logger
Mandatory parameters
Value
Paramet...

Načteno

edesky.cz/d/37763909

Meta

Nic nerozpoznáno


Z důvodu ochrany osobních údajů nemůžeme dokumenty zobrazovat neregistrovaným uživatelům.

Chcete vědět víc?

Další dokumenty od Geofyzikální ústav AV ČR v. v. i.
28. 10. 2026
28. 10. 2026
28. 10. 2026
28. 10. 2026
28. 10. 2026
  ...a další
Více dokumentů od Geofyzikální ústav AV ČR v. v. i.      Zasílat nové dokumenty emailem      Napište portálu edesky.cz